Overfill prevention should be a top focus in liquid transfer applications. Obviously, the risks of an overfill vary considerably depending on the media, but any overfill costs money and effort to clean up, especially when nearby equipment is in danger of being damaged.

Rail car, tank truck, and storage tank overfill prevention is necessary if these vessels contain liquids such as hazardous or costly chemicals, or petroleum products. Employees and the general public's health and safety are jeopardized, not to mention the financial costs associated with material clean-up costs plus the high cost of non-conformance fines. It is well worth the expense to implement an overfill protection system. Nobody wants to be the cause of a catastrophic mistake, but there is more to it than that. Companies that use a management system to prevent overfills may also see improvements in their day-to-day operating efficiency.

Liquid terminal operations are closely monitored to ensure that the appropriate equipment and procedures are in place. Whether you are transferring materials from rail cars, tank trucks, or storage tanks, Dixon has your overfill protection needs covered with our system-based approach.

Dixon ADS overfill protection systems span a wide range of liquid transfer and dry bulk processes, that include:

  • Petroleum products: gasoline, diesel, kerosene, and jet fuel
  • Biodiesel
  • Water-based products
  • Water/petroleum waste
  • Ether
  • Esters
  • Surfactants
  • Sulfuric acid
  • Amines
  • Molten sulfur
  • Sodium hydroxide
  • Methyl diphenyl diisocyanate (MDI)
  • Vinyl chloride monomer
  • Alcohol and methanol
  • Brine
  • Salt
  • Plastic pellets
  • Flour

 

Dixon ADS Products

A100 Outalarm® with Probe:

The ADS A100 Outalarm with a probe is specifically designed for liquid terminal operation, providing batch loading and overfill protection on rail cars and tank trucks, and is suitable for open and closed domes. Also, custom designs are available to meet your specific application.

outalarm_a100

Features:

  • Self-contained; no wires, tubing, or external power
  • Rugged weather-and corrosion-resistant construction
  • No moving parts, tip sensitive phase shift digital capacitance sensor for conductive and non-conductive liquid; conductivity sensor available for conductive liquids
  • Requires no calibration or adjustment
  • High-intensity audible and flashing visual outputs
  • Optional optoisolated solid-state contact output
  • Full, hard, graduated, laser-engraved rod
  • A100 operates up to 2,500 hours on a single 9V alkaline battery in standby mode
  • Adjustable insertion length through a standard 1/2" NPT fitting
  • Fail-safe, continuous battery monitor goes to alarm state on low battery

Approvals:

  • Intrinsically safe design per ANSI/UL 913 for Class I, Div I Groups A, B, C, and D Hazardous Areas

 

A210 ADS Spillguard® System:

The A210 ADS Spillguard is a shutdown and alarm system designed for rail cars, tank trucks, barges, and ships that are also suitable for open and closed domes.

spillguard system_a210

Features:
    Rugged, explosion-proof, weather-, chemical-, and corrosion-resistant LED status lights are visible through a glass cover Inserts into the tank through standard 1/2" NPT fitting The probe can be portable or permanently installed in the vessel Laser-engraved graduated rod with 1/4" graduations Probe-to-controller cable protected by stainless steel interlocking armor sheath and heavy-duty latching connectors at both ends Fail-safe design, unit trips in the event of an open or shorted cable or loss of power Choice of capacitance, conductivity, or single-point ultrasonic sensors Input power: 120 VAC, 240 VAC, or 24 VDC, 2.5 watts Output relay de-energizes on high level, broken or shorted sensor cables, or loss of power Sensor excitation open circuit voltage 8 VDC, short circuit current 8 mA with built-in FM-approved barrier Optional self-test feature, tilt, and ground verification interlocks, and latching circuit available

Approvals:

  • Cable connectors designed for repeated mating meet IP 65 mechanical and environmental specifications
  • FM, CSA HAZ Loc Class I Div I, Groups B, C, D, enclosure, and barrier components.


ADS Spillguard Probes:

spillguard probe_a200 series

A200-Series

ADS Spillguard Capacitance Probes
For use with materials with dielectric constant > 1.8; liquids, powders, and slurries.

Features:
  • 1/2" NPT sliding fitting standard, 3/4" fitting optional
  • Open dome adapter and washout fitting available
  • Tilt sensor optional

ADS Spillguard Conductivity Probes

For use with conductive liquids such as acids and water-based mixtures.

Features:

  • 1/2" NPT sliding fitting standard, 3/4" fitting optional
  • 50 PSIG, 150 PSIG, or 300 PSIG fittings available
  • Open dome adapter and washout fitting available
  • Tilt sensor option
  • Single electrode protected in housing
  • Dual electrodes are exposed for easy cleaning


ADS Outage Gauges:

ADS Outage Gauges are used to set level fill points for manual/visual control. They also measure outage requirements on mobile tanks.

Feature:
  • Open dome bracket
ads-outage-gauge_a800og4Standard Outage Gauge ADS outalarm outage gauge 5 in_A800OG5Outage Gauge with J bar

Dixon manufactures and supplies industry-leading overfill protection packages and accessories to support your liquid transfer needs. Here at Dixon, our customer's safety and well-being are one of our top priorities. We have sales professionals who can help you select the right product for your application, backed by our 24x7 technical support team. If you enjoyed this blog post, please share it with your colleagues.